A Case of T DRAIN Displacement Treated Conservatively
PDF
Cite
Share
Request
VOLUME: 1 ISSUE: 3
P: 242 - 244
1991

A Case of T DRAIN Displacement Treated Conservatively

Anatol J Gen Med Res 1991;1(3):242-244
1. SSK Tepecik Hastanesi I. Genel Cerrahi Kliniği, İzmir
2. SSK Afyon Hastanesi Cerrahi Servisi
No information available.
No information available
Received Date: 2015-06-26T14:43:34
PDF
Cite
Share
Request

Abstract

If the displacement of T drain occurs by 5th. day of operation, the drain should be replaced again by a reoperation. In our case, displacement occured at 3rd. postoperative day. The drain was kept inside and connected to an active aspiration system. After a close observation, patient did well without problem. Careful observation and active drainage of displaced T drain are well enough and may prevent some reoperations.

Keywords:
T - drain, Displacement, Complication